Induction Bearing Heater
Induction Bearing Extractor
Vel Induction heater (Type: VEL/BH*) is specially designed with intelligent microcontroller based controller heat and Mount Roller Bearing Inner Race, Coupling, Bush, Sleeve, Pinions, Gears, Axle box, Rotor Shaft Assemblies, End Fitting of Pressure Tube in PHWR etc
TECHNICAL SPECIFICATION:
TYPE | VEL/BH* |
Technology | Microcontroller based Electronic Control, Induction Heater, specifically designed and manufactured for mounting of Bearings, inner races etc. |
Incoming Voltage | 230V, 1phase, 50Hz. |
Output Power | 2-80 KVA |
Operational parameters | Time (0-99mins), Temperature (0 to 250°C, in step of 1°C), Power (0-100%) |
Maximum Temperature | 400°C |
Memory Backup | To set & save all the operational parameters for different jobs (99 no. of jobs) in rewritable memory (EEPROM) of the microcontroller |
MMI | Man Machine Interface is 4-line alpha numeric LCD display. The LCD Displays all set, operational and trip parameters etc. Five functional keys to set & save the operational parameter |
Induction Bearing Extractor
VEL High Frequency Induction Heater, Type: VEL/IBE*, is the latest state of art, intelligent microcontroller based electronic controls, solid state high frequency IGBT based Induction Heater specially designed for mounting / dismounting of Railway Shrink Fit Components such as such as Bearing Inner Races, Sleeves, Throwers, Retaining Collar, labyrinth, tube, distance piece etc. of Axle Wheel for various type of Electric Locos
TECHNICAL PARAMETER:
TYPE | VEL/IBE* |
Technology | Latest, Intelligent Microcontroller based Electronic Control, Solid State High Frequency Induction Heater, specifically designed and manufactured for mounting / dismounting of Railway Shrink Fit Components such as Bearing Inner Races, Sleeves, Throwers, Retaining Collar etc |
Incoming Voltage | 3 phase, 415V+10%, 50Hz 4wire system. |
Power Factor | >0.9 |
Output Power | 15-80 kW |
Output frequency | 3 to 15 kHz |
Control | The machine is cut off when the pre-set time or pre-set temperature is reached. |
Display | 20 character 4-line Alphanumeric LCD display for displaying various parameters such as Job No., Time (elapsed,set), Power (actual,set), Temperature (actual,set), error messagesetc |
Memory | Stores set parameters (Time, Temperature, Power) for 100 jobs |
Operation | Feature touch 5 keys on panel to set parameters etc |
Power control | Variable from 0-100% continuous |
Time control | 0-9.9 mins |
Temperature Control | 0-250°C. 250°C (max). |